The Flow Detective is the first sampling pump airflow calibrator to measure pulsation for ISO 13137 compliance. The device displays a red indicator if pulsation the 10% compliance level is exceeded. It measures the flow of air sampling pumps to within 2% accuracy and when used with the Casella Apex2, it can achieve closed loop automatic calibration, so nothing has to be set manually.
More infoLeyro Instruments is a specialized company in the manufacture, distribution and maintenance of calibration and measurement equipment. They provide solutions in relation with various sectors of the industry. They aim to provide the best solutions with the most accurate and intuitive technology in a key market for the production and service sectors. Nowadays each factory, research laboratory, university, office, hospital or facility new construction is a potential customer of their products.
Leyro's portable dry block temperature calibrator for temperature calibrations between -35ºC… 165ºC *. With ± 0.03ºC stability, ± 0.05ºC uniformity and ± 0.3ºC accuracy, it offers a versatile solution for calibrate thermocouples in industrial environments, offering excellent performance as well as fast response time. The LHC 40 is easy to use, thanks to its compact and lightweight design. Thanks to the large size of the insert, it has a large drilling capacity and can calibrate a large number of thermocouples at the same time. In addition to the standard insert (A), it has several types of optional inserts (B, C, D, E) to adapt to any need.
More infoPortable thermostatic temperature Calibration bath. THE FASTER IN THE WORLD. Temperature range -35ºC… 165ºC. It offers an accuracy of 0,3ºC in all the temperature range, a depth of inmersion of 190 mm and a diameter of 60 mm.
More info- Quick and simple calibration and fault detection of sensors and measuring chains for acceleration, velocity and displacement - Load independent vibration magnitude - Vibration magnitude of 10 m/s² (VC20) or selectable in 5 steps from 1 to 20 m/s² (VC21) - Quartz stabilized vibration frequency of 159.2 Hz (VC20) or selectable in 7 steps from 15.92 Hz to 1280 Hz (VC21) - Suitable for the calibration of whole-body human vibration meters to ISO 8041 and building vibration meters to DIN 4150-3 - Battery operated for mobile use - Traceable to PTB reference standard - Rugged design
More info- Quick and simple calibration and fault detection of sensors and measuring chains for acceleration, velocity and displacement - Load independent vibration magnitude - Vibration magnitude of 10 m/s² (VC20) or selectable in 5 steps from 1 to 20 m/s² (VC21) - Quartz stabilized vibration frequency of 159.2 Hz (VC20) or selectable in 7 steps from 15.92 Hz to 1280 Hz (VC21) - Suitable for the calibration of whole-body human vibration meters to ISO 8041 and building vibration meters to DIN 4150-3 - Battery operated for mobile use - Traceable to PTB reference standard - Rugged design
More infoClass 1 sound calibrator IEC 60942 Frequency 1 kHz 114 dB level Internal reference MEMS microphone Automatic power off
More infoClass 2 sound calibrator IEC 60942 Frequency 1 kHz 114 dB level Internal reference MEMS microphone Automatic power off
More infoSV 35 & SV 33 class 1 sound calibrators meeting IEC 60942:2003 SV 34 class 2 sound calibrator meeting IEC 60942:2003 Frequency 1 kHz ? 94 dB or 114 dB levels (SV 35) 114 dB level (SV 33, SV 34) Built-in reference microphoneSV 35 Class 1 Acoustic Calibrator produces an acoustic pressure of defined level 94 db & 114 dB at frequency of 1 kHz. The SV 35 is suitable for calibration of Class 1 and Class 2 sound level meters and dosimeters with 1/2 microphones. Unlike many others, the Svantek calibrators feature a robust housing that gives the comfort of a secure grip to the user. The interior design of our acoustic calibrators is based on the reference microphone and microprocessor controlled signal source including digital static pressure and temperature compensation.
More infoPortable Vibration Calibrator: SV 111 is a multi-frequency vibration calibrator designed for in-situ checks according to ISO 8041. The SV 111 is suitable for calibration checks of various types of vibration meters at different frequencies from 16 Hz up to 640 Hz. Depending on the selected frequency user may select level of calibration from 1 m/s2 to 10 m/s2. Shaker can be loaded with large weight up to 1 kilogram at 16 Hz. The design of the calibrator is based on the built-in triaxial reference accelerometer and microprocessor-controlled shaker. Following ISO 8041 requirement the reference accelerometer measures the cross-axis / transverse vibrations to detect interference on the calibration signal. Faults caused by transverse vibrations are indicated by three LEDS on the calibrator’s panel. This unique solution ensures the excellent stability of the calibration level & frequency independently from mass of the testing object. For calibration checks of tri-axial sensors set of dedicated adapters is available including a special adapter to Svantek whole-body sensors (seat-pads) for direct mounting on the shaker. Other types of vibration transducers can be conveniently attached using mounting stud, mounting disc or dedicated adapter.